Lab Journal

Emission spectra of Coumarin 1, Coumarin 151, Coumarin 7, Coumarin 6, Rhodamine 6G and Rhodamine B from 400 to 650 nm, under the title: Coumarins, rhodamines and fluorescein in solution. NorrChemica Lab Journal.

Coumarins, rhodamines and fluorescein in soluti...

A fluorescent dye can give a weaker signal, or emit at a different wavelength, than its data sheet states. Published absorption and emission maxima, molar absorption coefficients and quantum yields...

Coumarins, rhodamines and fluorescein in soluti...

A fluorescent dye can give a weaker signal, or emit at a different wavelength, than its data sheet states. Published absorption and emission maxima, molar absorption coefficients and quantum yields...

Cover: coupling reagents beyond the amide bond. COMU oxidises H-phosphonates, PyBroP activates a lactim C–OH, TCFH makes ketones, HBTU gives a one-vessel Curtius, CDI runs a Lossen; none dehydrates an amide.

Coupling reagents beyond the amide bond: oxidat...

Peptide coupling reagents are bought to make amides. Seven other reactions they do, from the oxidation of H-phosphonates by COMU to the Lossen rearrangement with CDI: which reagent does which,...

Coupling reagents beyond the amide bond: oxidat...

Peptide coupling reagents are bought to make amides. Seven other reactions they do, from the oxidation of H-phosphonates by COMU to the Lossen rearrangement with CDI: which reagent does which,...

Six staining solutions in bottles, hematoxylin, alcian blue, trypan blue, methylene blue, crystal violet and resazurin, each with the fault that most often stops it working. NorrChemica Lab Journal.

Why a staining solution stops working: hematoxy...

A staining solution that worked last month gives a weak or patchy result today. Six stains, and for each one the fault that most often causes it, what causes the...

Why a staining solution stops working: hematoxy...

A staining solution that worked last month gives a weak or patchy result today. Six stains, and for each one the fault that most often causes it, what causes the...

Cover: a powder bottle labelled dye content ≥85 %, a balance with dye powder in a weighing boat, and a volumetric flask of the dye solution.

Dye content on the label: why a stain at 85% is...

A stain labelled "dye content ≥85%" is not 15% impure. The figure is the share of the powder that is coloured compound, and most of the rest is water and...

Dye content on the label: why a stain at 85% is...

A stain labelled "dye content ≥85%" is not 15% impure. The figure is the share of the powder that is coloured compound, and most of the rest is water and...

Cover: radical coupling of a carboxylic acid and a boronic acid, with anhydrous TMAF above the reaction arrow and an alternating-current symbol below it.

Radical coupling of carboxylic acids and boroni...

Neutral boron + fluoride from TMAF + an electrode = new radical chemistry. A paper in Nature Chemistry (5 October 2026) joins alkyl carboxylic acids to alkylboronic acids by electrolysis,...

Radical coupling of carboxylic acids and boroni...

Neutral boron + fluoride from TMAF + an electrode = new radical chemistry. A paper in Nature Chemistry (5 October 2026) joins alkyl carboxylic acids to alkylboronic acids by electrolysis,...

Abstract gold-on-navy illustration of two molecular fragments joining at a glowing bond, representing amide and peptide coupling.

Choosing a Coupling Reagent for Amide and Pepti...

Two amide couplings that look identical on paper can give a clean product or a racemised mess, depending only on the reagent and additive. A practical guide to the carbodiimides,...

Choosing a Coupling Reagent for Amide and Pepti...

Two amide couplings that look identical on paper can give a clean product or a racemised mess, depending only on the reagent and additive. A practical guide to the carbodiimides,...